Novel lipoarabinomannan point-of-care tuberculosis test for people with HIV: a diagnostic accuracy study.

A new interesting article has been published in Lancet Infect Dis. 2019 Aug;19(8):852-861. doi: 10.1016/S1473-3099(19)30001-5. Epub 2019 May 30. and titled:

Novel lipoarabinomannan point-of-care tuberculosis test for people with HIV: a diagnostic accuracy study.

Authors of this article are:

Broger T, Sossen B, du Toit E, Kerkhoff AD, Schutz C, Ivanova Reipold E, Ward A, Barr DA, Macé A, Trollip A, Burton R, Ongarello S, Pinter A, Lowary TL, Boehme C, Nicol MP, Meintjes G, Denkinger CM.

A summary of the article is shown below:

BACKGROUND: Most tuberculosis-related deaths in people with HIV could be prevented with earlier diagnosis and treatment. The only commercially available tuberculosis point-of-care test (Alere Determine TB LAM Ag [AlereLAM]) has suboptimal sensitivity, which restricts its use in clinical practice. The novel Fujifilm SILVAMP TB LAM (FujiLAM) assay has been developed to improve the sensitivity of AlereLAM. We assessed the diagnostic accuracy of the FujiLAM assay for the detection of tuberculosis in hospital inpatients with HIV compared with the AlereLAM assay.METHODS: For this diagnostic accuracy study, we assessed biobanked urine samples obtained from the FIND Specimen Bank and the University of Cape Town Biobank, which had been collected from hospital inpatients (aged ≥18 years) with HIV during three independent prospective cohort studies done at two South African hospitals. Urine samples were tested using FujiLAM and AlereLAM assays. The conduct and reporting of each test was done blind to other test results. The primary objective was to assess the diagnostic accuracy of FujiLAM compared with AlereLAM, against microbiological and composite reference standards (including clinical diagnoses).FINDINGS: Between April 18, 2018, and May 3, 2018, urine samples from 968 hospital inpatients with HIV were evaluated. The prevalence of microbiologically-confirmed tuberculosis was 62% and the median CD4 count was 86 cells per μL. Using the microbiological reference standard, the estimated sensitivity of FujiLAM was 70·4% (95% CI 53·0 to 83·1) compared with 42·3% (31·7 to 51·8) for AlereLAM (difference 28·1%) and the estimated specificity of FujiLAM was 90·8% (86·0 to 94·4) and 95·0% (87·7-98·8) for AlereLAM (difference -4·2%). Against the composite reference standard, the specificity of both assays was higher (95·7% [92·0 to 98·0] for FujiLAM vs 98·2% [95·7 to 99·6] for AlereLAM; difference -2·5%), but the sensitivity of both assays was lower (64·9% [50·1 to 76·7] for FujiLAM vs 38·2% [28·1 to 47·3] for AlereLAM; difference 26·7%).INTERPRETATION: In comparison to AlereLAM, FujiLAM offers superior diagnostic sensitivity, while maintaining specificity, and could transform rapid point-of-care tuberculosis diagnosis for hospital inpatients with HIV. The applicability of FujiLAM for settings of intended use requires prospective assessment.FUNDING: Global Health Innovative Technology Fund, UK Department for International Development, Dutch Ministry of Foreign Affairs, Bill & Melinda Gates Foundation, German Federal Ministry of Education and Research, Australian Department of Foreign Affairs and Trade, Wellcome Trust, Department of Science and Technology and National Research Foundation of South Africa, and South African Medical Research Council.Copyright © 2019 Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.

Check out the article’s website on Pubmed for more information:

[link-preview url=https://www.ncbi.nlm.nih.gov/pubmed/31155318 forceshot=true]

This article is a good source of information and a good way to become familiar with topics such as: n/a.

New Chemicals from MOLECULAR DEPOT


New Proteins from MOLECULAR DEPOT


New Antibodies from MOLECULAR DEPOT


New Research Kits from MOLECULAR DEPOT

Molecular Depot

Your specialty peptide, proteins, antibodies and chemical compounds store.