Flow cytometric mepacrine fluorescence can be used for the exclusion of platelet dense granule deficiency.

A new interesting article has been published in J Thromb Haemost. 2019 Dec 9. doi: 10.1111/jth.14698. and titled:

Flow cytometric mepacrine fluorescence can be used for the exclusion of platelet dense granule deficiency.

Authors of this article are:

van Asten I, Blaauwgeers M, Granneman L, Heijnen HFG, Kruip MJHA, Beckers EAM, Coppens M, Eikenboom J, Tamminga RYJ, Pasterkamp G, Huisman A, van Galen KPM, Korporaal SJA, Schutgens REG, Urbanus RT.

A summary of the article is shown below:

BACKGROUND: δ-storage pool disease (δ-SPD) is a bleeding disorder characterized by a reduced number of platelet-dense granules. The diagnosis of δ-SPD depends on the measurement of platelet ADP content, but this test is time consuming and requires a relatively large blood volume. Flow cytometric analysis of platelet mepacrine uptake is a potential alternative, but this approach lacks validation, which precludes its use in a diagnostic setting.OBJECTIVES: To evaluate the performance of platelet mepacrine uptake as a diagnostic test for δ-SPD.PATIENTS/METHODS: Mepacrine fluorescence was determined with flow cytometry before and after platelet activation in 156 patients with a suspected platelet function disorder and compared with platelet ADP content as a reference test. Performance was analyzed with a receiver operating characteristic (ROC) curve.RESULTS: Eleven of 156 patients had δ-SPD based on platelet ADP content. Mepacrine fluorescence was inferior to platelet ADP content in identifying patients with δ-SPD, but both mepacrine uptake (area under the ROC curve [AUC] 0.87) and mepacrine release after platelet activation (AUC 0.80) had good discriminative ability. In our tertiary reference center, mepacrine uptake showed high negative predicitive value (97%) with low positive predictive value (35%). Combined with a negative likelihood ratio of 0.1, these data indicate that mepacrine uptake can be used to exclude δ-SPD in patients with a bleeding tendency.CONCLUSION: Mepacrine fluorescence can be used as a screening tool to exclude δ-SPD in a large number of patients with a suspected platelet function disorder.© 2019 The Authors. Journal of Thrombosis and Haemostasis published by Wiley Periodicals, Inc. on behalf of International Society on Thrombosis and Haemostasis.

Check out the article’s website on Pubmed for more information:

[link-preview url=https://www.ncbi.nlm.nih.gov/pubmed/31815339 forceshot=true]

This article is a good source of information and a good way to become familiar with topics such as: blood platelets; flow cytometry; platelet function testing; platelet storage pool deficiency; quinacrine.


NativeFolder: The Only Bacterial Culture Medium for the Expression of Soluble Proteins


Interference Test Kit for Assay Validation


Rheumatoid Factor Interference Blocker


New Antibodies from MOLECULAR DEPOT


New Proteins from MOLECULAR DEPOT


New Chemicals from MOLECULAR DEPOT

Molecular Depot

Your specialty peptide, proteins, antibodies and chemical compounds store.