Catalog Number: K2010008G2 (1 mL) Glycerol for Interference Testing is a high quality research product used as highly concentrated glycerol solution (10 mg/mL) for spiking into specimens to study the interference of glycerol in various assays. Custom bulk orders of this product are available upon request.
Catalog Number: K2010008I (1 mL) Intralipid for Interference Testing is a high quality research product used as highly concentrated intralipid solution (20%) for spiking into specimens to study the interference of intralipids in various assays. Custom bulk orders of this product are available upon request.
Catalog #: K2010008H (100 mg) Cholesterol provided as amorphous white powder. Cholesterol can be directly spiked in specimens to test Cholesterol interference in various assays.
Catalog #: K2010008U Highly concentrated solution of Urea (200 mg/mL) provided with the corresponding diluent. Solution can be spiked in specimen to test Urea interference in various assays.
Catalog #: K2010008C Highly concentrated solution of Creatinine (50 mg/mL) provided with the corresponding diluent. Solution can be spiked in specimen to test creatinine interference in various assays.
Catalog #: K2010008B Highly concentrated solution of Biotin (200 ug/mL) provided with the corresponding diluent. Solution can be spiked in specimen to test biotin interference in various assays.
Catalog #: K2010001B Highly concentrated solution of free bilirubin(20 mg/mL) provided with the corresponding diluent. Solution can be spiked in specimen to test free bilirubin interference.
Catalog #: K2010001C Highly concentrated solution of conjugated bilirubin(20 mg/mL) provided with the corresponding diluent. Solution can be spiked in specimen to test conjugated bilirubin interference.
Catalog #: K2010001A Highly concentrated solution of L-ascorbic acid (176 mg/mL; 1.0 M) provided with the corresponding diluent. Solution can be spiked in specimen to test ascorbic acid interference.
Catalog #: K2010001D Highly concentrated solution of human hemoglobin (200 mg/mL) provided with the corresponding diluent. Solution can be spiked in specimen to test hemoglobin interference.
Catalog #: S2010006 Unique donor serum samples with high levels (600 ng/mL to over 10,000 ng/mL) of Human Anti-Mouse Antibodies (HAMA). HAMA titer has been established with an FDA-approved ELISA method. These samples can be used to test HAMA interference in immunoassays. This product is for in vitro research use only. This product is not for diagnostic or therapeutic procedures.
Catalog #: K2010009 HAMA Interference Kit is a collection of 6 serum samples aimed at assessing the interference of Human Anti-Mouse Antibodies (HAMA) in immunoassays. The kit includes five HAMA-positive serum samples (PS1 to PS5) with HAMA concentrations up to 200 ng/mL (as established by a HAMA ELISA assay) as well as one HAMA-negative serum sample (NS). This kit is…
Catalog #: K2010008 Interference Test Kit EXTRA contains 9 endogenous substances to use in routine assay interference testing. Interference Test Kit EXTRA includes concentrated stock solutions of Biotin, Creatinine, EDTA, Glucose, Glycerol, Intralipid, Pyruvate, Urea and Cholesterol. Interference Test Kit conveniently includes the diluent to be used when testing each of the interfering substances. This kit can be used in…
Catalog #: K2010007 A ready-to-use kit to test Rheumatoid Factor (RF) interference in immunoassays. The kit includes a concentrated RF solution (human plasma containing an extremely high level of RF, 2 mL) and the corresponding plasma diluent (Rheumatoid Factor Diluent, 8 mL). The kit also includes a protocol to test to RF Interference. Rheumatoid Factor and Rheumatoid Factor Diluent are…
Catalog #: S2010002 Rheumatoid factor (RF) is a collection of autoimmune antibodies that target the Fc region of immunoglobulins G (IgG). RF is the first series of antibodies that was found in Rheumatoid Arthritis (RA). Rheumatoid Factor Diluent (catalog #S2010002) consists of human plasma containing undetectable levels of RF (~ 0 IU/mL). This product can be used to test the…
Catalog #: S2010001 (1 mL) Rheumatoid factor (RF) is a collection of autoimmune antibodies that target the Fc region of immunoglobulins G (IgG). RF is the first series of antibodies that was found in Rheumatoid Arthritis (RA). Rheumatoid Factor Solution (catalog #S2010001) consists of human plasma containing an extremely high level of RF (≥1900 IU/mL). This product can be used…
Catalog #: A2010010 - 10 mg The presence in human serum of Human Anti-Mouse antibodies (HAMA) is a major concern in immunoassays. Indeed, HAMA are often associated with inaccurate results and false positives because they can bind to both capture and detection antibodies and can generate non-specific immunoassay signals. The provided HAMA Blocking Reagent specifically binds to HAMA, minimizing their…
Catalog #: A2010009 (100 mg) Rheumatoid Factor (RF) interference is a major issue when testing the performance of immunoassays. RF and other autoimmune antibodies present in the serum of Rheumatoid Arthritis patients can, presumably, bridge capture and detection antibodies in a non-specific fashion. This phenomenon leads to the generation of non-specific immunoassay signals and the recovery of higher than expected…
Catalog #: K2010001 Interference Test Kit containing six endogenous substances to use in assay routine interference testing. Interference Test Kit includes concentrated stock solutions of Ascorbic Acid (176 mg/mL), Free Bilirubin (20 mg/mL), Conjugated Bilirubin (20 mg/mL), Human Hemoglobin (200 mg/mL), Human Serum Proteins (20 g/dL), and a Triglycerides mix (1000 mg/mL). Interference Test Kit conveniently includes the diluents to…
Catalog #: C2010001 (1 mL at 1000 mg/mL ) A mixture of five saturated triglycerides that can be used for interference studies or chromatography. Mixture consists of 20% (m/m) Triacetin (C2:0), 20% (m/m) Tributyrin (C4:0), 20% (m/m) Tricaproin (C6:0), 20% (m/m) Tricaprylin (C8:0) and 20% (m/m) Tricaprin (C10:0). Available in neat solution of 1000 mg/mL (1 mL). Live Enquiry about…