Evaluation of a Rapid Syphilis Test in an Emergency Department Setting in Detroit, Michigan.

A new interesting article has been published in Sex Transm Dis. 2019 Jul;46(7):429-433. doi: 10.1097/OLQ.0000000000000993. and titled:

Evaluation of a Rapid Syphilis Test in an Emergency Department Setting in Detroit, Michigan.

Authors of this article are:

Fakile YF, Markowitz N, Zhu W, Mumby K, Dankerlui D, McCormick JK, Ham DC, Hopkins A, Manteuffel J, Sun Y, Huang YA, Peters PJ, Hoover KW.

A summary of the article is shown below:

BACKGROUND: Syphilis transmission can be prevented by prompt diagnosis and treatment of primary and secondary infection. We evaluated the performance of a point-of-care rapid syphilis treponemal (RST) test in an emergency department (ED) setting.METHODS: Between June 2015 and April 2016, men aged 18 to 34 years seeking services in a Detroit ED, and with no history of syphilis, were screened for syphilis with the RST test, rapid plasma reagin (RPR) test, and Treponema pallidum particle agglutination assay (TP-PA). A positive reference standard was both a reactive RPR and a reactive TP-PA. We compared test results in self-reported men who have sex with men (MSM) to non-MSM.RESULTS: Among 965 participants, 10.9% of RST tests were reactive in MSM and only 1.5% in non-MSM (P < 0.001). Sensitivity of the RST test was 76.9% and specificity was 99.0% (positive predictive value, 50.0%) compared with the positive reference standard. Three discordant specimens found negative with the RST test but positive with the reference standard had an RPR titer of 1:1, compared with 10 specimens with concordant positive results that had a median RPR titer of 1:16. The RST sensitivity was 50.0% (positive predictive value, 68.4%) compared to the TP-PA test alone. Among men seeking care in an ED, the RST detected 76.9% of participants with a reactive RPR and TP-PA.CONCLUSIONS: The RST test detected all of the participants with an RPR titer ≥1:2 but less than 20% of participants with a positive TP-PA and negative RPR. The RST test was useful to detect a high proportion of participants with an active syphilis in an urban ED.
Check out the article’s website on Pubmed for more information:



This article is a good source of information and a good way to become familiar with topics such as: n/a.

New Chemicals from MOLECULAR DEPOT


New Proteins from MOLECULAR DEPOT


New Antibodies from MOLECULAR DEPOT


New Research Kits from MOLECULAR DEPOT

Molecular Depot

Your specialty peptide, proteins, antibodies and chemical compounds store.