European Biological Variation Study (EuBIVAS): Within- and Between-Subject Biological Variation Data for 15 Frequently Measured Proteins.

A new interesting article has been published in Clin Chem. 2019 Aug;65(8):1031-1041. doi: 10.1373/clinchem.2019.304618. Epub 2019 Jun 6. and titled:

European Biological Variation Study (EuBIVAS): Within- and Between-Subject Biological Variation Data for 15 Frequently Measured Proteins.

Authors of this article are:

Carobene A, Aarsand AK, Guerra E, Bartlett WA, Coşkun A, Díaz-Garzón J, Fernandez-Calle P, Jonker N, Locatelli M, Sandberg S, Ceriotti F; European Federation of Clinical Chemistry and Laboratory Medicine Working Group on Biological Variation.

A summary of the article is shown below:

BACKGROUND: The European Biological Variation Study (EuBIVAS) was established to deliver rigorously determined data for biological variation (BV). Here, EuBIVAS-based BV estimates are provided for α1-acid glycoprotein, α1-antitrypsin, albumin, β2-microglobulin, ceruloplasmin, complement component 3, complement component 4, C-reactive protein (CRP), cystatin C, haptoglobin, IgA, IgG, IgM, soluble transferrin receptor (sTfR), and transferrin (Trf), together with their associated analytical performance specifications (APSs) and reference change values (RCVs).METHOD: Serum samples from weekly blood samplings of 91 healthy study participants (38 males and 53 females, ages 21-69 years old) over 10 consecutive weeks in 6 European laboratories were stored at -80 °C before duplicate analysis on a Roche Cobas c702. Outlier and variance homogeneity analyses were performed followed by CV-ANOVA on trend-corrected data if relevant, to determine BV and analytical variation estimates with CI and the associated RCV.RESULTS: For the acute phase proteins, several participants experienced mild inflammatory episodes during the study, requiring exclusion of 7% of the 25290 results. Within-subject BV (CVI) estimates for specific proteins obtained in our study were lower than those available in the online 2014 BV database, except for Trf, whereas between-subject BV (CVG) estimates were similar. CVI and CVG estimates for sTfR, which have not previously been published, were 6.0% and 19.1%, respectively.CONCLUSIONS: In addition to new BV estimates for sTfR, this EuBIVAS substudy generated more demanding APS for frequently requested plasma specific proteins. APS for CRP should not be calculated from BV data except when CRP is used as a risk factor for cardiovascular disease.© 2019 American Association for Clinical Chemistry.

Check out the article’s website on Pubmed for more information:



This article is a good source of information and a good way to become familiar with topics such as: n/a.

New Chemicals from MOLECULAR DEPOT


New Proteins from MOLECULAR DEPOT


New Antibodies from MOLECULAR DEPOT


New Research Kits from MOLECULAR DEPOT

Molecular Depot

Your specialty peptide, proteins, antibodies and chemical compounds store.